- root@fbaddy:/usr/home/local # smartctl -a /dev/ada0
- smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.1-RELEASE-p10 amd64] (local build)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Green
- Device Model: WDC WD20EZRX-00D8PB0
- Serial Number: WD-WMC4N0F1SFL5
- LU WWN Device Id: 5 0014ee 0ae990a9e
- Firmware Version: 80.00A80
- User Capacity: 2,000,398,934,016 bytes [2.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Wed May 16 20:42:42 2018 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (32400) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 326) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x7035) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 169 168 021 Pre-fail Always - 6508
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 220
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 062 062 000 Old_age Always - 27744
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 137
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 103
- 193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 616
- 194 Temperature_Celsius 0x0022 116 103 000 Old_age Always - 34
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 27743 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@fbaddy:/usr/home/local # smartctl -a /dev/ada1
- smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.1-RELEASE-p10 amd64] (local build)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Green
- Device Model: WDC WD20EZRX-00D8PB0
- Serial Number: WD-WMC4M0F7Y4KS
- LU WWN Device Id: 5 0014ee 60574f269
- Firmware Version: 80.00A80
- User Capacity: 2,000,398,934,016 bytes [2.00 TB]
- Sector Sizes: 512 bytes logical, 4096 bytes physical
- Rotation Rate: 5400 rpm
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ACS-2 (minor revision not indicated)
- SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
- Local Time is: Wed May 16 20:43:01 2018 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (28680) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 289) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x7035) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 176 173 021 Pre-fail Always - 4191
- 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 175
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 064 064 000 Old_age Always - 26486
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 91
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 65
- 193 Load_Cycle_Count 0x0032 166 166 000 Old_age Always - 104361
- 194 Temperature_Celsius 0x0022 112 105 000 Old_age Always - 35
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 26484 -
- # 2 Short offline Completed without error 00% 26478 -
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.
- root@fbaddy:/usr/home/local # smartctl -a /dev/ada2
- smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.1-RELEASE-p10 amd64] (local build)
- Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Western Digital Caviar Green (AF)
- Device Model: WDC WD20EARS-00S8B1
- Serial Number: WD-WCAVY2845250
- LU WWN Device Id: 5 0014ee 259751864
- Firmware Version: 80.00A80
- User Capacity: 2,000,398,934,016 bytes [2.00 TB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA8-ACS (minor revision not indicated)
- SATA Version is: SATA 2.6, 3.0 Gb/s
- Local Time is: Wed May 16 20:43:12 2018 PDT
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x84) Offline data collection activity
- was suspended by an interrupting command from host.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: (39960) seconds.
- Offline data collection
- capabilities: (0x7b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 2) minutes.
- Extended self-test routine
- recommended polling time: ( 455) minutes.
- Conveyance self-test routine
- recommended polling time: ( 5) minutes.
- SCT capabilities: (0x3031) SCT Status supported.
- SCT Feature Control supported.
- SCT Data Table supported.
- SMART Attributes Data Structure revision number: 16
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0027 178 138 021 Pre-fail Always - 8075
- 4 Start_Stop_Count 0x0032 094 094 000 Old_age Always - 6387
- 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
- 9 Power_On_Hours 0x0032 038 038 000 Old_age Always - 45280
- 10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
- 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 583
- 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 294
- 193 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 1226472
- 194 Temperature_Celsius 0x0022 114 094 000 Old_age Always - 38
- 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
- 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
- 198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 0
- 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0008 200 200 000 Old_age Offline - 0
- SMART Error Log Version: 1
- No Errors Logged
smartctl long test of first three drives