1. --------------------------------------------
  2. CCRID Product Title
  3. --------------------------------------------
  4. 2726999 BROADBAND_SPICE S-parameter model checker: Passivity and causality report from any file
  5. 2718214 CELSIUS Mapping relationship issue occurs in the vertical .cfd file
  6. 2647312 CLARITY The airbox is different when using parametric import and non-parametric import in Clarity 3D Workbench
  7. 2653811 CLARITY Standard volume/surface seeding has no impact on mesh
  8. 2686605 CLARITY Clarity 3D Layout gets stuck in the AFS stage
  9. 2704441 CLARITY Clarity AFS0 is not efficient
  10. 2712819 CLARITY Optimality simulation stopped with an error for a 16 parameters case
  11. 2722868 CLARITY Clarity 3D Workbench quasi static solver succeeds in 3D inductance extraction but fails in sweeping mode
  12. 2731236 CLARITY S-parameter results are not correct for one signal net
  13. 2733867 CLARITY Parametric import in Clarity 3D Workbench does not preserve metal shapes
  14. 2734558 CLARITY Low frequency sweep is failing in Clarity
  15. 2741029 CLARITY Unnecessary license checkouts cause LMESH to fail on AWS using HF3
  16. 2729682 OPTIMIZEPI The EMI Optimization option remains disabled despite complete setup
  17. 2722499 POWERDC Applying the PowerTree topology in PowerDC does not complete the PowerTree application wizard
  18. 2728437 POWERDC Using the Tcl command DisplaNodesOnCircuitNodePads causes the GUI to exit unexpectedly
  19. 2728449 POWERDC The Tcl command DisplaNodesOnCircuitNodePads shows nodes inside vias
  20. 2709420 POWERSI Frequency sampling is incorrect from the DCfitted_customized model
  21. 2722007 POWERSI Capacitor model assignment error occurs in PowerSI
  22. 2723559 POWERSI PowerSI exits unexpectedly during shape processing
  23. 2734811 POWERSI DC_Fitted snp output file is missing in PDN Extraction using PowerSI
  24. 2693519 SIGRITY_SUITE Fanout routing moves to other layer when swept in Clarity 3D Layout HSSO flow
  25. 2706495 SIGRITY_SUITE XtractIM produces different mapping file starting from Sigrity2022.1 HF2
  26. 2727959 SIGRITY_SUITE Pad Stack window in PowerSI does not display correctly
  27. 2730550 SIGRITY_SUITE The port generation flow for multiterminal circuits in Clarity 3D Layout does not generate the S-parameter results
  28. 2730949 SIGRITY_SUITE Failed to check port connection error occurs in Clarity 3D Layout when the Cut & Stitch method is used
  29. 2737253 SPEED2000 SPEEDEM failed to read IBIS model
  30. 2682592 TRANSLATOR Pads are missing after translation
  31. 2741685 TRANSLATOR Change in padstack names when importing .tgz file into PowerSI