- $ sudo smartctl -a /dev/sda
- [sudo] password for arch:
- smartctl 7.1 2019-12-30 r5022 [x86_64-linux-5.9.4-arch1-1] (local build)
- Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
- === START OF INFORMATION SECTION ===
- Model Family: Seagate Barracuda 7200.10
- Device Model: ST3160215AS
- Serial Number: 6RAAA8P8
- Firmware Version: 4.AAB
- User Capacity: 160,041,885,696 bytes [160 GB]
- Sector Size: 512 bytes logical/physical
- Device is: In smartctl database [for details use: -P show]
- ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
- Local Time is: Fri Nov 6 16:41:24 2020 IST
- SMART support is: Available - device has SMART capability.
- SMART support is: Enabled
- === START OF READ SMART DATA SECTION ===
- SMART overall-health self-assessment test result: PASSED
- General SMART Values:
- Offline data collection status: (0x82) Offline data collection activity
- was completed without error.
- Auto Offline Data Collection: Enabled.
- Self-test execution status: ( 0) The previous self-test routine completed
- without error or no self-test has ever
- been run.
- Total time to complete Offline
- data collection: ( 430) seconds.
- Offline data collection
- capabilities: (0x5b) SMART execute Offline immediate.
- Auto Offline data collection on/off support.
- Suspend Offline collection upon new
- command.
- Offline surface scan supported.
- Self-test supported.
- No Conveyance Self-test supported.
- Selective Self-test supported.
- SMART capabilities: (0x0003) Saves SMART data before entering
- power-saving mode.
- Supports SMART auto save timer.
- Error logging capability: (0x01) Error logging supported.
- General Purpose Logging supported.
- Short self-test routine
- recommended polling time: ( 1) minutes.
- Extended self-test routine
- recommended polling time: ( 54) minutes.
- SMART Attributes Data Structure revision number: 10
- Vendor Specific SMART Attributes with Thresholds:
- ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
- 1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
- 3 Spin_Up_Time 0x0003 100 097 000 Pre-fail Always - 0
- 4 Start_Stop_Count 0x0032 089 089 020 Old_age Always - 12237
- 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
- 7 Seek_Error_Rate 0x000f 088 060 030 Pre-fail Always - 713692648
- 9 Power_On_Hours 0x0032 078 078 000 Old_age Always - 19865
- 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
- 12 Power_Cycle_Count 0x0032 088 088 020 Old_age Always - 12379
- 187 Reported_Uncorrect 0x0032 001 001 000 Old_age Always - 115
- 189 High_Fly_Writes 0x003a 090 090 000 Old_age Always - 10
- 190 Airflow_Temperature_Cel 0x0022 059 050 045 Old_age Always - 41 (Min/Max 41/42)
- 194 Temperature_Celsius 0x0022 041 050 000 Old_age Always - 41 (0 20 0 0 0)
- 195 Hardware_ECC_Recovered 0x001a 073 067 000 Old_age Always - 6074783
- 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 2
- 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 2
- 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0
- 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0
- 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0
- SMART Error Log Version: 1
- ATA Error Count: 121 (device log contains only the most recent five errors)
- CR = Command Register [HEX]
- FR = Features Register [HEX]
- SC = Sector Count Register [HEX]
- SN = Sector Number Register [HEX]
- CL = Cylinder Low Register [HEX]
- CH = Cylinder High Register [HEX]
- DH = Device/Head Register [HEX]
- DC = Device Command Register [HEX]
- ER = Error register [HEX]
- ST = Status register [HEX]
- Powered_Up_Time is measured from power on, and printed as
- DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
- SS=sec, and sss=millisec. It "wraps" after 49.710 days.
- Error 121 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
- 35 00 01 71 5a 0d e0 00 00:08:52.207 WRITE DMA EXT
- 25 00 01 71 5a 0d e0 00 00:08:55.415 READ DMA EXT
- 25 00 01 72 5a 0d e0 00 00:08:55.415 READ DMA EXT
- 25 00 01 71 5a 0d e0 00 00:08:55.391 READ DMA EXT
- Error 120 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 00 01 72 5a 0d e0 00 00:08:52.207 READ DMA EXT
- 25 00 01 71 5a 0d e0 00 00:08:52.207 READ DMA EXT
- 25 00 01 70 5a 0d e0 00 00:08:52.206 READ DMA EXT
- 25 00 01 6f 5a 0d e0 00 00:08:52.206 READ DMA EXT
- 25 00 01 6e 5a 0d e0 00 00:08:52.206 READ DMA EXT
- Error 119 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 41 00 01 72 5a 0d e0 00 00:43:33.999 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
- 41 00 01 71 5a 0d e0 00 00:43:33.991 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
- 41 00 01 70 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
- 41 00 01 6f 5a 0d e0 00 00:43:33.983 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
- 41 00 01 6e 5a 0d e0 00 00:43:33.974 READ VERIFY SECTOR(S) (w/o retry) [OBS-5]
- Error 118 occurred at disk power-on lifetime: 520 hours (21 days + 16 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 42 00 00 00 5a 0d e0 00 00:43:30.570 READ VERIFY SECTOR(S) EXT
- 42 00 00 00 59 0d e0 00 00:43:30.595 READ VERIFY SECTOR(S) EXT
- 42 00 00 00 58 0d e0 00 00:43:30.592 READ VERIFY SECTOR(S) EXT
- 42 00 00 00 57 0d e0 00 00:43:30.591 READ VERIFY SECTOR(S) EXT
- 42 00 00 00 56 0d e0 00 00:43:30.589 READ VERIFY SECTOR(S) EXT
- Error 117 occurred at disk power-on lifetime: 519 hours (21 days + 15 hours)
- When the command that caused the error occurred, the device was active or idle.
- After command completion occurred, registers were:
- ER ST SC SN CL CH DH
- -- -- -- -- -- -- --
- 40 51 00 72 5a 0d e0 Error: UNC at LBA = 0x000d5a72 = 875122
- Commands leading to the command that caused the error were:
- CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
- -- -- -- -- -- -- -- -- ---------------- --------------------
- 25 03 40 70 5a 0d e0 00 00:02:40.034 READ DMA EXT
- 25 03 01 00 00 00 e0 00 00:02:40.023 READ DMA EXT
- 35 03 08 8f dc 94 e0 00 00:02:40.023 WRITE DMA EXT
- 35 03 10 f7 23 91 e0 00 00:02:40.023 WRITE DMA EXT
- 25 03 1e 81 71 90 e0 00 00:02:40.023 READ DMA EXT
- SMART Self-test log structure revision number 1
- Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
- # 1 Extended offline Completed without error 00% 13440 -
- # 2 Short offline Completed without error 00% 12632 -
- # 3 Short offline Completed without error 00% 11525 -
- # 4 Extended offline Completed without error 00% 10486 -
- # 5 Short offline Completed without error 00% 3978 -
- # 6 Extended offline Aborted by host 90% 3715 -
- # 7 Short offline Completed without error 00% 3714 -
- # 8 Extended offline Completed: read failure 90% 118 11322720
- # 9 Extended offline Completed: read failure 90% 118 11322720
- #10 Short offline Completed: read failure 90% 118 11322720
- 3 of 3 failed self-tests are outdated by newer successful extended offline self-test # 1
- SMART Selective self-test log data structure revision number 1
- SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
- 1 0 0 Not_testing
- 2 0 0 Not_testing
- 3 0 0 Not_testing
- 4 0 0 Not_testing
- 5 0 0 Not_testing
- Selective self-test flags (0x0):
- After scanning selected spans, do NOT read-scan remainder of disk.
- If Selective self-test is pending on power-up, resume after 0 minute delay.